Knowledgebase
Inclinometer.dll does fails to load in DREDGEPACK
Posted by Christian Shaw, Last modified by
Notice
Undefined index: editedstaff (C:/inetpub/wwwroot/Support/__swift/cache/8ffb74eb8fb5aeb3f7fb2e375265078e.php:44)
Copy to clipboard:
on 14 August 2015 03:45 PM

Inclinometer.dll does fails to load in DREDGEPACK

 

This can be caused by the Inclinometer.dll having a function of draft in HYPACK hardware and having the option "Generate Output Messages" checked for the driver. 

 

Because this driver can be used in an advanced state where you can have two inclinometers on the same dredge are with them having different depths and articulations these options are necessary. For standard cutter suction setups, you do not need draft and generate output messages turned on in Hardware for Inclinometer.dll .